Microclimate Comfort
Calculates the perceived 'Feels Like' temperature using Fast Apparent Temperature or UTCI (full Broede et al. 2012 polynomial). In UTCI mode the mean radiant temperature is not computed: it is approximated as air temperature + 15 C x Solar Factor, which dominates the uncertainty.
Overview
Calculates the perceived 'Feels Like' temperature using Fast Apparent Temperature or Precise UTCI.
Inputs (7)
- Points (Point): Analysis points.
- Air Temp (Number): Air temperature in Celsius.
- Humidity (Number): Relative humidity in %.
- Wind Speed (Number): Wind speed in m/s at 10m height.
- Solar Factor (Number): Solar exposure from 0.0 (shade) to 1.0 (sun).
- Method (Integer): 0 = Fast Apparent Temp, 1 = Precise UTCI
- Run (Boolean): Optional. False = skip the analysis and keep showing the last results (cached). Share one toggle with the Analysis Dashboard to switch everything on/off together.
Outputs (6)
- Points (Point): Analysis points.
- Feels Like (Number): Perceived temperature in Celsius.
- Category (Text): Comfort category label.
- Colors (Colour): Gradient color mapping.
- Dashboard Data (Text): JSON Legend Data
- Info (Text): Method, assumptions, simplifications and references.
Method, assumptions and simplifications
The same notes appear in the component's Info output.
Method
- Each point takes Air Temp, Humidity, Wind Speed and Solar Factor from the lists by index (the last value is reused if a list is shorter; defaults 25 °C, 50 %, 1 m/s, 1.0).
- Method 0: Apparent Temperature AT = T + 0.33 e - 0.70 v - 4.0, e = RH/100 × 6.105 × exp(17.27 T / (237.7 + T)) hPa, plus 4 °C × Solar Factor.
- Method 1: mean radiant temperature is not computed: it is approximated as T + 15 °C × Solar Factor, which dominates the uncertainty of the UTCI result.
- UTCI uses the full 210-term operational polynomial of Bröde et al. (2012) in T, v, Tmrt - T and vapour pressure, ported from pythermalcomfort (MIT), with saturation vapour pressure from Hardy (1998) as in the official UTCI program; results match the pythermalcomfort reference values within 0.1 °C.
- Inputs outside the UTCI validity range (T -50 to 50 °C, Tmrt - T -30 to 70 °C, wind 0.5 to 17 m/s, vapour pressure 0 to 5 kPa) are clamped to it and a warning gives the number of points affected; those results are indicative only.
- Categories: AT uses fixed bands (40, 32, 27, 20, 10, 0 °C); UTCI follows the official 10-class scale, from Extreme Heat Stress above 46 °C to Extreme Cold Stress below -40 °C.
- Colours run from dark blue at -10 °C to dark red at 40 °C through 5 fixed stops.
Assumptions
- Inputs are point values for the same moment (one hour or design condition); the points only carry the results, the tool does not look at geometry.
- Wind Speed is at 10 m height; Solar Factor 0-1 comes from a sun or shade study.
Simplifications and limits
- Radiation is a fixed add-on (+4 °C AT, +15 °C Tmrt in full sun), not a computed mean radiant temperature.
- No clothing, activity or local wind reduction; AT categories are not from a standard.
Workflow
- Sun Hours Analysis exposure -> Solar Factor; wind results (Fast CFD) -> Wind Speed; EPW hour values -> Air Temp and Humidity.
References
- Steadman R.G. (1994), Norms of apparent temperature in Australia, Australian Meteorological Magazine 43; the Australian Bureau of Meteorology apparent temperature formula.
- Bröde P. et al. (2012), Deriving the operational procedure for the Universal Thermal Climate Index (UTCI), International Journal of Biometeorology 56.
- Tartarini F. and Schiavon S. (2020), pythermalcomfort: a Python package for thermal comfort research, SoftwareX 12 (MIT licence): source of the ported UTCI polynomial.
- Hardy B. (1998), ITS-90 formulations for vapor pressure, frostpoint temperature, dewpoint temperature and enhancement factors.